Rubber Lining Autoclave
Rubber Lining Autoclave Specification
- Product Type
- Rubber Lining Autoclave
- Color
- Silver
- Usage
- Laboratory
- Material
- Stainless Steel
- Type
- Dry Heat Sterilization Equipments
- Chamber Size
- Custom built (Varies per model)
- Chamber Thickness
- As per design requirements
- Outer Size
- Customized as per requirement
- Compressed Air
- 4-6 kg/cm
- Door Type
- Manual or Hydraulic
- Design Pressure
- 2.5 kg/cm to 3.0 kg/cm
- Working Pressure
- Up to 2.1 kg/cm
- Design Temperature
- Up to 140C
- Heat Uniform
- +/- 2C
- Insulation
- Mineral Wool / Glass Wool / Ceramic Fiber
- Net Weight
- As per model size
- Recording Parameters
- Digital / Chart Recorder
- Spraying Mode
- Rotary / Static
- Outer Trolley
- Available
- Inner Trolley
- Available
- Spraying Piping
- Stainless Steel 304/316
- Steam
- Saturated Steam
- Sterilizing Temperature
- 121C to 134C
- Working Temperature
- Up to 134C
- Sterilization Time
- 0-99 min
- Temperature Scope
- Ambient to 134C
- Piping System
- Stainless Steel construction
- Valves
- Safety, Vent, Vacuum, Pressure
- Power Consumption
- Custom as per size
- Available Capacity
- 100 Liters to 5,000 Liters
- Standards Followed
- ASME / ISO / GMP Guidelines
- Control System
- PLC or Microprocessor Based
- Mount Type
- Floor Mounted
- Chamber Shape
- Horizontal Cylindrical
- Accessories
- Cycle Printer, Data Logger, Air Filter, Loading Cart
- Door Sealing Type
- Silicon Gasket / Inflatable Seal
- Power Source
- Electric / Steam
- Surface Finish
- Polished / Matt Finish
- Safety Features
- Pressure Release Valve, Over Temperature Protection
Rubber Lining Autoclave Trade Information
- Minimum Order Quantity
- 1 Unit
- Payment Terms
- Cash in Advance (CID), Cash Advance (CA)
- Supply Ability
- 1 Unit Per Month
- Delivery Time
- 2 Months
- Main Export Market(s)
- Western Europe, Australia, Eastern Europe, Central America, Africa, Middle East, South America, Asia, North America
- Main Domestic Market
- All India
About Rubber Lining Autoclave
Owing to our extensive years of industry experience and market understanding, we are engaged in manufacturing and exporting a wide gamut of Rubber Lining Autoclave. Under the observation of our professionals, the offered autoclave is manufactured using supreme quality materials. This is used for processing the materials and is demanded for its rubber lining design. In addition, this Rubber Lining Autoclave is available in diverse specifications at marginal prices.
Features:
- Excellent functionality
- Energy efficient
- Longer service life
Rubber Lining Autoclave
- Porgrammable Functions
- SCADA Control
- Fully Automatic
- Optional Cooling System Available
- Direct/ Indirect types Available
- Easy Controls
- High Safety
Product Details
Applications | For Composite/Hybrid Rubber Lining & Rubber Products |
Automatic | Fully Automatic & Programmable |
Vessel Design | As per ASME S.8 D.1 |
Safety Measures | 4 Layer Safety |
Design Temp | upto 250 DegreeC |
Design Pressure | Upto 12 Bar |
Payload Capacity | 0.5 to 50 MT |
Working Area | 0.3m to 10m |
Heating | Steam/ Indirect Thermic Oil |
Controls | PLC+ HMI Controls with Interlocks& Alarms |
Uses | Especially for Rubber Products |
Precision Sterilization for Laboratories
Our Rubber Lining Autoclave ensures efficient and uniform sterilization thanks to its state-of-the-art rotary or static spraying mode and premium insulation. Designed for laboratory use, it handles a broad temperature range (ambient to 134C) and is capable of sterilizing at pressures up to 2.1 kg/cm. The polished or matt finish not only adds to its visual appeal but aids in easy cleaning, supporting high hygiene standards required in critical environments.
Built for Safety and Compliance
Safety is paramount, with multiple valves (safety, vent, vacuum, pressure) and over temperature protection integrated into each model. The equipment is constructed according to international standards such as ASME, ISO, and GMP guidelines, ensuring compliance for laboratories and research institutions. Digital or chart recorders log sterilization parameters for traceability, while features like pressure release valves further enhance operational safety.
FAQs of Rubber Lining Autoclave:
Q: How does the Rubber Lining Autoclave maintain airtight sealing during sterilization?
A: The autoclave uses a high-quality silicon gasket or an inflatable seal at the door, providing a secure and airtight closure that prevents leakage during operation. This ensures optimal temperature and pressure retention inside the sterilization chamber.Q: What process is followed to ensure effective dry heat sterilization in this autoclave?
A: The device achieves dry heat sterilization by circulating hot air at controlled temperatures between 121C and 134C, for adjustable durations up to 99 minutes. Uniform heat distribution (+/- 2C) is maintained via a rotary or static spraying system, ensuring thorough sterilization of all materials.Q: When should the autoclaves safety features be checked or maintained?
A: It is recommended to check the functionality of safety features, such as pressure release valves and over temperature protection, before every sterilization cycle. Regular scheduled maintenance should also be performed as per manufacturer guidelines to ensure continuous safe operation.Q: Where can this autoclave be installed, and what are its mounting options?
A: This model is designed for floor mounting, making it suitable for laboratories or industrial sterilization rooms with adequate space and ventilation. Customized outer sizes are available to fit specific installation requirements.Q: What are the main benefits of using a stainless steel, rubber-lined autoclave for laboratory sterilization?
A: Stainless steel construction ensures durability, corrosion resistance, and easy cleaning, while the rubber lining offers enhanced chemical resistance and longevity. Additionally, modular capacity options (1005,000 liters) allow laboratories to choose the optimal size for their workload.Q: Which control systems are available and how do they enhance the autoclaves operation?
A: The autoclave features either PLC or microprocessor-based control systems, allowing precise programming of temperature, time, and pressure. These advanced controls improve process accuracy, support automated cycles, and ensure documentation of every sterilization run through digital or chart recorders.Q: How can the autoclaves performance be monitored and recorded during sterilization cycles?
A: Performance can be tracked using integrated cycle printers, data loggers, and digital or chart recorders, which document parameters such as temperature, pressure, and cycle duration. This provides critical records for quality assurance and regulatory compliance.
Price:
- 50
- 100
- 200
- 250
- 500
- 1000+
More Products in Industrial Autoclaves Category
Rubber Vulcanizing Autoclave
Price 500000 INR
Minimum Order Quantity : 1 Unit
Color : Silver
Type : Pressure Steam Sterilization Equipments
Usage : Laboratory
Power Consumption : Depends on chamber size, generally 1030 kW
Disposable / Waste Treatment Autoclaves
Price 500000 INR
Minimum Order Quantity : 1 Unit
Color : Silver
Type : Other, Waste Treatment Autoclaves
Usage : Laboratory
Power Consumption : 8 kW
Industrial Autoclave
Price 500000 INR
Minimum Order Quantity : 1 Unit
Color : Silver
Type : Ultrasonic Sterilization Equipments
Usage : Laboratory
Power Consumption : 815 kW
Mini autoclaves
Price 500000 INR
Minimum Order Quantity : 1 Unit
Color : Silver
Type : Mini autoclaves, Other
Usage : Laboratory
Power Consumption : 1500 Watt (W)



Send Inquiry